    Office Lighting Design Guide

    Workplace lighting fundamentals, lux, UGR, CCT, energy density and the operational scenes every modern office should be designed around.

    Written by Srikrishna ElloreReviewed by Ashwamedha Lighting StudioLast updated June 19, 2026Based on 108+ live projects
    Office Lighting Design Guide

    The Goal of Office Lighting

    Visual comfort across an eight-hour workday. Not brightness. Not novelty. Comfort and clarity.

    Lux Targets

    ZoneLux
    Open-plan desks300–500 lux at desk height
    Meeting rooms300 lux with dimming
    Reception200–300 lux with accents
    Circulation100–150 lux
    Focus rooms300 lux with personal control

    UGR, Non-Negotiable

    Open-plan offices must be designed at UGR ≤ 19, evaluated from realistic observer positions. UGR ≤ 16 is required for VDT-intensive spaces. Glare drives complaints faster than any other lighting issue.

    Colour Temperature

    4000K is the safe default for offices. Tunable white (3000K–5000K) is increasingly used to support circadian rhythm across the workday.

    Energy Density

    Modern office lighting should easily come in below 8 W/m². Combined with daylight harvesting and occupancy sensing, 5–6 W/m² is achievable.

    Common Mistakes

    • Pendants without UGR data
    • No daylight integration on perimeter zones
    • Cool CCT in client-facing reception areas
    • No PIR or daylight sensors
    Lux ≥ target. UGR ≤ 19. CCT around 4000K. W/m² ≤ 8. That is the office lighting test.

    Lighting Intelligence by Alya

    At Ashwamedha Design Solutions, this is part of our Lighting Intelligence practice, every recommendation is validated through DIALux simulation, lux calculations and visual comfort analysis before it reaches a construction site. Alya, our lighting intelligence platform, packages this thinking into reusable design tools.

    Frequently Asked Questions

    What is the minimum lux for an open-plan desk?+

    300 lux on the working plane, with 500 lux preferred for paper-intensive work.

    How is UGR measured?+

    By calculation in DIALux from realistic observer positions. It cannot be measured with a lux meter on site.

    Should I use tunable white?+

    Yes for high-occupancy offices and any space where staff work 8+ hours.